| Parameter |
Sym |
Min |
Typical |
Max |
Unit |
Note |
| Nominal Load |
Fnom |
|
10 |
|
tonne |
- For NZ 50kg
rail
- Without
mechanical
damage
|
| Operating Temperature |
Top |
-10 |
|
+50 |
C° |
- Within
specified
performance
limits
|
| Storage Temperature |
Ts |
(-40) |
|
(+70) |
C° |
- Without
electrical
damage
|
| Temperature Change Rate |
dT/dt |
|
|
5 |
C°
/hr |
- Within
specified
performance
limits
|
| Supply Voltage |
Vs |
|
15 |
(30) |
V |
|
| Gauge-casing Voltage |
Vgs |
|
|
(100) |
V |
- Without
electrical
damage
|
| No Load Output |
Z |
-40 |
0 |
+40 |
µV/V |
|
| Span (output for Fnom) |
|
|
350 |
|
µV/V |
|
| Linearity |
L |
|
|
0.1 |
% |
|
| Zero Drift |
Tz |
|
|
0.5 |
µV/V
/C° |
- Average
over
0 C° -
50 C°
|
| Span Drift |
Ts |
|
|
0.001 |
%
/C° |
|
| Input Resistance |
Ri |
|
754 |
|
Ohm |
|
| Output Resistance |
Ro |
697 |
700 |
703 |
Ohm |
|
| Gauge-casing Resistance |
Rgs |
10 |
|
|
Gig-ohms |
|